Purple Screen of Death (PSOD)

11/20

Iscsi PSOD caused by a faulty NIC

Source:  Mike Laverick

Submitted by: Mike Laverick
Date: 13 December, 2006
Hardware: HP DL 385
Build: 3.0.0
Cause: Iscsi PSOD caused by a faulty NIC used with the Software Initiator – if you look closely it has a great message “Console Opps!”
Resolution: Changed NIC behind vmkernel storage port group

View All Photo Stories

Start the conversation

Send me notifications when other members comment.

Please create a username to comment.